Empirical therapy advisor

Before culture results are back: how likely is each antibiotic to cover the pathogen of a patient like this one, in this ward, given the last 12 months of results and today's alerts.

Patient

More options · any onset · target 80 % · 2024-12-08
Based on 615 first isolates · SURG · Skin / wound infection · 2023-12-10 → 2024-12-08
Surgery
Per-organism detail: SURG wound resistance view →
No single agent reaches 80 % coverage for this profile. Highest coverage without active warning:
vancomycin 53 % (49 %–56 %)
Best two-drug combination: vancomycin + meropenem covers 99 % (98 %–99 %)
Take cultures before treatment; consider a combination and discuss with infectious diseases if the patient is severely ill.
Not covered: Pseudomonas aeruginosa (15 %), Escherichia coli (13 %), Proteus mirabilis (7 %)
AntibioticCoverage, 12 months (95 % CI)12 mo4 wk
vancomycin VAN
trend · Staphylococcus aureus Gram-positive only
53 %
57 %
n = 42
meropenem MEM
trend · Pseudomonas aeruginosa reserve
46 %
43 %
n = 42
piperacillin-tazobactam TZP
trend · Pseudomonas aeruginosa broad spectrum
44 %
43 %
n = 42
43 %
40 %
n = 42
clindamycin CLI
trend · Staphylococcus aureus Gram-positive only
41 %
38 %
n = 42
ceftriaxone CRO
trend · Escherichia coli
29 %
31 %
n = 42
27 %
26 %
n = 42
23 %
43 %
n = 42
14 %
7 %
n = 42
mecillinam MEC
not for this site
0 %
0 %
n = 42
trimethoprim TMP
not for this site
0 %
0 %
n = 42
nitrofurantoin NIT
not for this site
0 %
0 %
n = 42

Most likely organisms for this profile

Staphylococcus aureus
43 %
Pseudomonas aeruginosa
15 %
Escherichia coli
13 %
Enterococcus faecalis
9 %
Proteus mirabilis
7 %
Klebsiella pneumoniae
6 %

Decision support only: coverage is the share of first isolates from similar patients that were susceptible (an organism not tested for a drug counts as not covered). It does not replace local treatment guidelines, allergy and severity assessment, or clinical judgement. The black tick on each bar is the coverage target; the bracket is the 95 % confidence interval.

AEI · Tyks Laboratoriot × Mylab · JunctionX Turku. Synteettinen aineisto; EARS-Net-luvut: ECDC.