Empirical therapy advisor

Before culture results are back: how likely is each antibiotic to cover the pathogen of a patient like this one, in this ward, given the last 12 months of results and today's alerts.

Patient

More options · any onset · target 80 % · 2025-09-07
Based on 1256 first isolates · PHC-S · Cystitis (lower UTI) · 2024-09-08 → 2025-09-07
Health centre South
Per-organism detail: PHC-S urine resistance view → ⚠ 1 active alert in PHC-S: they are taken into account below. View alerts →
Narrowest option reaching 80 % coverage, no active warning
nitrofurantoin 82 % (80 %–84 %)
No tissue or blood levels: cystitis only.
Not covered: Proteus mirabilis (8 %), Pseudomonas aeruginosa (5 %), Klebsiella pneumoniae (4 %)
AntibioticCoverage, 12 months (95 % CI)12 mo4 wk
nitrofurantoin NIT
trend · Escherichia coli lower UTI only
82 %
85 %
n = 109
meropenem MEM
trend · Escherichia coli reserve
81 %
84 %
n = 109
piperacillin-tazobactam TZP
trend · Escherichia coli broad spectrum
78 %
83 %
n = 109
ciprofloxacin CIP
trend · Escherichia coli
76 %
81 %
n = 109
mecillinam MEC
trend · Escherichia coli lower UTI only
74 %
77 %
n = 109
ceftriaxone CRO
trend · Escherichia coli
74 %
80 %
n = 109
trimethoprim TMP
trend · Escherichia coli lower UTI only
71 %
71 %
n = 109
69 %
75 %
n = 109
52 %
57 %
n = 109
vancomycin VAN
trend · Enterococcus faecalis Gram-positive only
⚠ VRE case in the ward
15 %
11 %
n = 109
4 %
4 %
n = 109
clindamycin CLI
trend · Staphylococcus aureus Gram-positive only
4 %
2 %
n = 109

Most likely organisms for this profile

Escherichia coli
49 %
Klebsiella pneumoniae
14 %
Enterococcus faecalis
11 %
Proteus mirabilis
8 %
Pseudomonas aeruginosa
5 %
Citrobacter freundii
4 %

Decision support only: coverage is the share of first isolates from similar patients that were susceptible (an organism not tested for a drug counts as not covered). It does not replace local treatment guidelines, allergy and severity assessment, or clinical judgement. The black tick on each bar is the coverage target; the bracket is the 95 % confidence interval.